Sprayer Nozzle Types Explained: Flat Fan, Cone, Air Induction and Flood — remote control agricultural sprayer article

Short answer: Flat fan nozzles give an even pattern for boom spraying. Cone nozzles give fine droplets for foliage and airblast work. Air induction nozzles make larger droplets that drift less. Flood nozzles give a wide pattern at low pressure. Choose by target, product label and drift risk.

Main types

TypePatternTypical use
Flat fanEven sheetBoom spraying, herbicide
Hollow coneRing, fine dropletsFoliage, airblast
Full coneFilled circleSoil-applied products
Air inductionCoarse, air-filled dropletsDrift reduction
FloodWide, low pressureBoomless, wide swaths

Droplet size

Finer droplets cover better but drift more. Coarser droplets drift less but may cover less. The product label often states a droplet class.

Pressure

Each nozzle works in a pressure range. Outside it, the pattern and droplet size change.

Materials

Brass wears quickly; stainless steel and ceramic last longer. Replace worn nozzles as a set.

Choosing

  • Read the product label.
  • Consider drift risk at the site.
  • Match output to speed and rate.
  • Check the pattern with water.

MERI sprayers

MERI ME-RCS boom versions carry 8 to 16 nozzles depending on model (customizable), and airblast versions use a fan with a ring of nozzles. See the pump and nozzle guide.

Maintenance

Clean with a soft brush, never wire, and check output each season.

Nozzle colour codes

Many nozzles use a standard colour code for flow size. The colour tells you the output at a reference pressure; check the maker’s chart for exact figures. Using the same colour across a boom is a quick visual check that sizes match.

When to replace

  • Output more than about 10% above new.
  • Visible damage or uneven pattern.
  • After using abrasive products.
  • At least each season on heavily used sprayers.

Matching nozzle to the job

JobCommon choiceWhy
Herbicide strip or boomFlat fan or air inductionEven pattern; lower drift
Orchard or vineyard canopyHollow coneFine droplets into foliage
Drift-sensitive siteAir inductionCoarse droplets
Soil-applied productFull cone or flat fanEven ground cover

Always follow the product label for nozzle type and droplet class.

MERI tracked sprayer with a guarded airblast fan and spray lines, parked on a factory floor
MERI tracked sprayer with a guarded airblast fan and spray lines, parked on a factory floor.

Worked example: checking a set

A boom has 10 nozzles. At working pressure, each is caught for one minute. Nine give close to the same output, and one gives noticeably more. The worn one is not the only problem: if one is worn, the others have had the same hours. The grower replaces the full set, rechecks output and recalculates the rate. The same test takes about twenty minutes and is worth doing at the start of each season.

For the rate calculation, rate (L/ha) = nozzle output (L/min) × 600 ÷ (speed km/h × nozzle spacing m).

Cleaning and storage

  • Flush the system with clean water after each use.
  • Remove nozzles and filters; soak and clean with a soft brush.
  • Never use wire or a pin in the orifice.
  • Store nozzles dry in a labelled box by type and size.
  • Keep a spare set of the nozzles you use most.
MERI tracked sprayer with a 100 L tank and 6-nozzle system (MERI video library).

Common mistakes

  • Mixing nozzle types or sizes on one boom.
  • Raising pressure to fix a low rate.
  • Ignoring the droplet class on the label.
  • Replacing only the worst nozzle.

Changing nozzle types during the season

Many sprayers carry more than one nozzle type. Change them in a set order so nothing is missed.

  • Flush the boom with clean water before removing nozzles.
  • Fit the new nozzles and check each one sits square and seals.
  • Run water at working pressure and look at each spray pattern.
  • Check the output of a few nozzles with a jug and stopwatch.
  • Record the nozzle type, size and date in the sprayer log.

On a MERI ME-RCS boom version with 8 to 16 nozzles, this takes a short time and avoids spraying a block with the wrong droplet size.

Related MERI pages

Frequently asked questions

Which nozzle is used for boom herbicide spraying?

Usually flat fan.

Which nozzle reduces drift?

Air induction nozzles.

What do cone nozzles do?

Give fine droplets for foliage and airblast work.

How many nozzles do ME-RCS boom versions carry?

8 to 16 depending on model (customizable).

Send us your site details

Tell us the job, area, slope and country. MERI replies within 24 hours.

Ask MERI

Need a agricultural sprayer recommendation for your terrain or project?

Get a Quote
Get a Quote